GAS ANALYZERS & ANALYTICAL TECHNOLOGIES

FTC220

FTC220

  • ♦  Small ( 75 x 50 x 50 mm3 ) Thermal Conductivity (TC) Detector for Gas Analysis
  • ♦  Precise and long-term stable thermal conductivity measurement.
  • ♦  Control of ambient air or connection to measuring gas via ¼-inch female thread.
  • ♦  Teflon membrane as protection against condensate or contamination.
  • ♦  Fast response with a T90 time of less than 10sec.
  • ♦  Potential-free 4-20mA output, configurable through RS232.

EXTRAS

Protection Against Corrosion

Protection Against Corrosion

Protection Against Condensate & Dust

Protection Against Condensate & Dust

Technical Details

Dimensions without connectors; weight; 145mm x 80mm x 85mm; max. 1800g
Power supply 24V DC (18V to 36V), 700mA
Ambient temperature range -5°C to 50°C, other on request
Linearity < 1% of range
Warm up time About 30min; 1h for small ranges
Flow rate 40 l/h to 150 l/h; 60 l/h -80 l/h recommended
T90-time < 1 sec at flow rate higher 60 l/h
Noise < 1% of smallest range
Drift at zero point < 2% of smallest range per week
Repeatability < 1% of range
Error due to change of ambient temperature < 1% of smallest range per 10°C
Error due to change of flow at 80 1/h < 1% of smallest range per 10 l/h
Gas pressure Max.2MPa(20 bar)
Error due to change of pressure (above 800hPa abs.) < 1% of smallest range oer 10hPa

Binary Gas Combinations

Measuring Gas Carrier Gas Basis Range Smallest Range Smallest Suppressed Zero Range Multi Gas Mode MGM
Measuring GasH2 Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 0.5% Smallest suppressed zero range98% – 100% Multi Gas Mode MGMYes
Measuring GasO2 Carrier GasN2 Basis Range0% – 100% Smallest Range0% – 15% Smallest suppressed zero range85% – 100% Multi Gas Mode MGMYes
Measuring GasHe Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 0.8% Smallest suppressed zero range97% – 100% Multi Gas Mode MGMYes
Measuring GasCO2 Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 3% Smallest suppressed zero range96% – 100% Multi Gas Mode MGMYes
Measuring GasN2 Carrier GasAr Basis Range0% – 100% Smallest Range0% – 3% Smallest suppressed zero range97% – 100% Multi Gas Mode MGMYes
Measuring GasO2 Carrier GasAr Basis Range0% – 100% Smallest Range0% – 2% Smallest suppressed zero range97% – 100% Multi Gas Mode MGMYes
Measuring GasH2 Carrier GasAr Basis Range0% – 100% Smallest Range0% – 0.4% Smallest suppressed zero range99% – 100% Multi Gas Mode MGMYes
Measuring GasHe Carrier GasAr Basis Range0% – 100% Smallest Range0% – 0.5% Smallest suppressed zero range98% – 100% Multi Gas Mode MGMYes
Measuring GasCO2 Carrier GasAr Basis Range0% – 60% Smallest Range0% – 10% Smallest suppressed zero range Multi Gas Mode MGMYes
Measuring GasAr Carrier GasCO2 Basis Range40% – 100% Smallest Range Smallest suppressed zero range80% – 100% Multi Gas Mode MGMYes
Measuring GasCH4 Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 2% Smallest suppressed zero range96% – 100% Multi Gas Mode MGMYes
Measuring GasCH4 Carrier GasAr Basis Range0% – 100% Smallest Range0% – 1.5% Smallest suppressed zero range97% – 100% Multi Gas Mode MGMYes
Measuring GasAr Carrier GasO2 Basis Range0% – 100% Smallest Range0% – 3% Smallest suppressed zero range96% – 100% Multi Gas Mode MGMYes
Measuring GasN2 Carrier GasH2 Basis Range0% – 100% Smallest Range0% – 2% Smallest suppressed zero range99.5% – 100% Multi Gas Mode MGMYes
Measuring GasO2 Carrier GasCO2 Basis Range0% – 100% Smallest Range0% – 3% Smallest suppressed zero range96% – 100% Multi Gas Mode MGMYes
Measuring GasH2 Carrier GasHe Basis Range20% – 100% Smallest Range20% – 40% Smallest suppressed zero range85% – 100% Multi Gas Mode MGM 
Measuring GasH2 Carrier GasCH4 Basis Range0% – 100% Smallest Range0% – 0.5% Smallest suppressed zero range98% – 100% Multi Gas Mode MGM 
Measuring GasH2 Carrier GasCO2 Basis Range0% – 100% Smallest Range0% – 0.5% Smallest suppressed zero range98% – 100% Multi Gas Mode MGM 
Measuring GasSF6 Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 2% Smallest suppressed zero range96% – 100% Multi Gas Mode MGM 
Measuring GasNO2 Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 5% Smallest suppressed zero range96% – 100% Multi Gas Mode MGM 
Measuring GasH2 Carrier GasO2 Basis Range0% – 100% Smallest Range0% – 4% Smallest suppressed zero range97% – 100% Multi Gas Mode MGM 
Measuring GasAr Carrier GasXe Basis Range0% – 100% Smallest Range0% – 3% Smallest suppressed zero range99% – 100% Multi Gas Mode MGM 
Measuring GasNe Carrier GasAr Basis Range0% – 100% Smallest Range0% – 1.5% Smallest suppressed zero range99% – 100% Multi Gas Mode MGM 
Measuring GasKr Carrier GasAr Basis Range0% – 100% Smallest Range0% – 2% Smallest suppressed zero range96% – 100% Multi Gas Mode MGM 
Measuring GasR125 Carrier GasN2 or Air Basis Range0% – 100% Smallest Range0% – 4% Smallest suppressed zero range98% – 100% Multi Gas Mode MGM 

Contact us

If you are unsure, whether the listed devices fit your application, please specify your process in your enquiry. The Messkonzept GmbH technical sales team will work out the best solution for your process with you.

Contact Info

Contact Center : ( +49 ) 69 530 564 44

fax : ( +49 ) 69 530 564 45

e-mail:   info@messkonzept.de

Contact Center :
( +49 ) 69 530 564 44

fax : ( +49 ) 69 530 564 45

e-mail:   info@messkonzept.de

By submitting the data entered in the contact form by clicking on the button below, you declare that you have read the privacy policy and that you agree that the data provided will be collected and stored electronically.

The data is used only strictly earmarked for processing and answering your request.

By submitting the contact form you agree to the processing. You may revoke your consent at any time with future effect. In case of cancellation your data will be deleted immediately.

HOW CAN WE HELP YOU?

Please enable JavaScript in your browser to complete this form.
Please notice our privacy policy.